Ratified by the Spanish Standardisation Association in June 2020.
Main changes:
- Extension of the scope of the standard to domestic use: oven mitts/gloves.
- Gloves that reach a level 3 or 4 of any thermal property must reach at least a level 3 in flame propagation. Otherwise, the maximum level that may be reached in the relevant thermal property shall be level 2.
- Propagation limited to flame: prohibition of hole formation. Reduction of maximum post-combustion time for level 1. Change in ignition timing.
- Heat by contact. Obligation to test any material coming in contact with heat.
- Tear resistance. This trial is included.
- Convective heat. The test is performed without reinforcement.
- New pictogram, for gloves without flame protection.
- A minimum length is introduced when resistance against small molten metal splashes is present.
- After heat resistance tests, the samples must not suffer signs of melting or holes.
MINIMUM LENGTH OF THE TESTED GLOVES FOR E OR F
|
SIZE
|
LENGTH
|
5
|
290
|
6
|
300
|
7
|
310
|
8
|
320
|
9
|
330
|
10
|
340
|
11
|
350
|
12
|
360
|
13
|
370
|
A - Flame Behaviour
Changes in method and table. To perform the test, the ignition time now goes from 15 to 10" and the post-ignition time for level 1 goes from 20 to 15".
LEVEL OF PREFORMANCE
|
POST-INFLAMMATION TIME
|
POST IGNITION TIME
|
1
|
≤ 15
|
Not required
|
2
|
≤ 10
|
≤ 120
|
3
|
≤ 3
|
≤ 25
|
4
|
≤ 2
|
≤ 5
|
B - Heat by contact
Changes in the test method. In EN407:2004 only the palm is tested, whereas with EN407:2020 any other point that may come into contact is tested.
- Contact temperature
- Threshold time (S)
LEVEL OF PERFORMANCE
|
CONTACT TEMPERATURE
|
THRESHOLD TIME (S
|
1
|
100
|
≥ 15
|
2
|
250
|
≥ 15
|
3
|
350
|
≥ 15
|
4
|
500
|
≥ 15
|
C - Convective heat
Changes in the test method. From EN373 to ENISO9185:2007
LEVEL OF PERFORMANCE
|
HTI HEAT TRANSFER RATE
|
1
|
≥ 4
|
2
|
≥ 7
|
3
|
≥ 10
|
4
|
≥ 18
|
D - Radiant heat
There are no modifications. Internal layers must not show signs of melting or show holes.
LEVEL OF PERFORMANCE
|
HEAT TRANSFER RATE T3
|
1
|
≥ 7
|
2
|
≥ 20
|
3
|
≥ 50
|
4
|
≥ 95
|
E - Small splashes
There are no modifications. Internal and external layers may not be melted or pierced.
LEVEL OF PERFORMANCE
|
NUMBER OF DROPS
|
1
|
≥ 5
|
2
|
≥ 15
|
3
|
≥ 25
|
4
|
≥ 35
|
F - Large splashes
Changes in the test method.
LEVEL OF PERFORMANCE
|
CAST IRON (G)
|
1
|
30
|
2
|
60
|
3
|
120
|
4
|
300
|